Product Description
Innovative rolling design is adopted for FS-A20 Automatic Film Sealer, which can effectively avoid sample loss
and spatial cross-infection. It can be applied in conventional PCR Polymerase Chain Reaction) and fluorescence
QPCR(Qualitative Polymerase Chain Reaction). The machine is easy for operation, 4 modes are available
(pressure-sensitive film, adhesive film,0.1 mL PCR 8-strip tubes 0.2 mL PCR 8-strip tubes ), flexible to set software
parameters and rolling value. Rolling frequency can be moderated according to the requirement of the experiment
so that an assortment of brands of pressure-sensitive films and reaction plates can be well applicable.
OperationSteps
(01) Plug in the power cord, turn on the power switch, the screen will light up, and the instrument will perform a self-check;
(02) After passing the self-test, the screen displays the main interface, which is the mode selection interface;
(03) The corresponding mode can be selected according to the sealing film requirements: PS film (pressure-sensitive film mode),
0.1 mL Tube (0.1 mL 8 capping mode), Adhesive film (adhesive film mode), 0.2 mL Tube (0.2 mL 8 Joint gland mode) ;
(04) Select the mode, place the corresponding adapter, 96-well sealing adapter; 384-well sealing adapter and 8-strip tubes gland adapter;
(05)Set the icon in the upper right corner to enter the parameter setting interface to modify the rolling times and positions;
(06)Rolling times (1-99) and Rolling Pressure 1-3 are adjustable.
(07) Click Save to return to the operation interface;
(08) Pressure sensitive sealing film and adhesive sealing film: place the prepared sample in the PCR plate, tear off the sealing film
and stick it, and then put the PCR plate with the film on the sealer. Note that the wells should be aligned and flat; 8-strip tubes
grand: place the prepared sample in the 8-strip tubes, place the 8-strip tube on the film
(09) Press START, the instrument automatically enters the working chamber, and automatically seals/capping according to
different working modes;
(10) At the end of the operation, the instrument automatically exits the warehouse, and the screen displays Finished;
(11) Take out the PCR plate with the membrane sealed/the 8 tubes with the cap pressed.
Note: If the operation or sample is wrong, you need to stop the operation and take out the PCR plate, click the stop operation
button, and the instrument can directly exit the compartment door.
Warning ! Please do not directly touch the PCR plate during operation to avoid physical injury or sample loss.
BasicParameters:
Model |
FS-A20 |
Dimensions (L*W*H) |
362*178*291 mm |
Reaction Plate |
PCR reaction plate without skirt, half skirt, full skirt, Elisa plate,0.1mL/0.2 mL PCR 8-strip tubes |
Sealing Film |
PCR sealer film (pressure-sensitive, adhesive film) |
Running Times |
1-99 |
RollingPosition |
1-3 |
Weight |
7kg |
첫번째 리뷰의 주인공이 되세요!
등록된 상품문의가 없습니다.
배송안내
1)배송지역
전국 배송
2) 배송비
100,000원 미만 상품 구매시에는 배송료가 착불로 고객부담이며, 100,000원 이상 상품 구매시에는 배송료가 무료입니다.(구매합계액기준, 단, 제주도 및 기타 도서지역은 별도로 항공료가 추가됩니다.
3) 배송기간
일반지역 : 1~3일 소요(공휴일 제외)
산간지방 및 섬 지역(공휴일 제외) : 3~7일 소요
대금지급방법이 무통장 입금일 경우에는 입금 확인된 날부터 계산합니다.
주문의 폭주, 천재지변, 배송 과정에 차질이 발생한 경우 등에는 배송이 지연될 수 있음을 양지해 주시기 바랍니다.
4)배송조회
주문한 상품의 현재 배송상황을 확인 할 수 있습니다
반품/교환 안내
1)반품/교환/환불 가능한 경우
2)반품/교환/환불이 불가능한 경우
3)환불안내
사용한 제품은 반품이 불가능하므로 고객님들의 신중한 결정 부탁드립니다.
반품 금액은 상품과 상품의 무게에 따라, 지역에 따라 다소 차이가 날 수 있음을 알려드립니다.
자세한 문의를 원하시면 전화상담이나 (주)애큐리서치코리아 고객센터 게시판을 이용해 주시면 됩니다.
|
Copyright©2012 by AccuResearch Korea, Inc. All Rights Reserved. Hosting by GETMALL
KCP 매매보호(에크로) 서비스
고객님은 안전거래를 위해 모든거래 결제시 저희 쇼핑몰에서
가입한 KCP 전자 결제의 매매보호(에스크로) 서비스를 이용하실 수
있습니다.